{"id":4481,"date":"2014-07-31T10:02:07","date_gmt":"2014-07-31T10:02:07","guid":{"rendered":"http:\/\/tadafzar.com\/components-mobile-radio-stations-2\/"},"modified":"2014-12-14T13:14:41","modified_gmt":"2014-12-14T13:14:41","slug":"components-mobile-radio-stations","status":"publish","type":"post","link":"https:\/\/www.tadafzar.com\/en\/components-mobile-radio-stations\/","title":{"rendered":"Components for  Mobile Radio Stations"},"content":{"rendered":"<p><div class=\"brochure-dl\"><a class=\"tip-top tooltipstered\" href=\"http:\/\/files.telegaertner.com\/7114\/1043\/8836\/Mobile_Radio_Base_Stations.pdf\" target=\"_blank\" data-tip=\"PDF File \/ Download\"><img decoding=\"async\" data-src=\"\/images\/PDF.jpg\" alt=\"Brochure\" src=\"data:image\/gif;base64,R0lGODlhAQABAAAAACH5BAEKAAEALAAAAAABAAEAAAICTAEAOw==\" class=\"lazyload\"><noscript><img decoding=\"async\" src=\"\/images\/PDF.jpg\" alt=\"Brochure\"><\/noscript>Brochure Download<\/a><\/div><br \/>\n<img fetchpriority=\"high\" decoding=\"async\" class=\"ccm-image-block\" src=\"http:\/\/files.telegaertner.com\/7613\/8201\/8324\/Mobilfunk_teaser.jpg\" alt=\"\" width=\"800\" height=\"274\" border=\"0\" \/><\/p>\n<h1 style=\"text-align: left;\">RF Components, Fiber Optic and RJ45 Components<\/h1>\n<p class=\"teaser\" style=\"text-align: left;\">Many different connecting components are used in mobile radio base stations: from coaxial connectors, jumper cords and surge protection to RJ45 plugs, patch cables and FO connectors. Our &#8220;Components for Mobile Radio Base Stations&#8221; brochure provides an overview of the complete product portfolio.<\/p>\n<h2 style=\"text-align: left;\">Classic transmission of RF signals over coaxial cables<\/h2>\n<p style=\"text-align: left;\">Transmission and reception signals are transmitted by carrier frequencies between 700 MHz and 2.7 GHz, depending on the mobile radio generation and network. Low-attenuation corrugated cables of different diameters are used to minimise the attenuation losses between the base station and the antenna. Typically, these corrugated cables are dimensioned 1\/2&#8243;, 7\/8&#8243;, 1 1\/4&#8243; and 1 5\/8&#8243;. Teleg\u00e4rtner offers matching connectors of the SIM<em>Fix<\/em>\u00ae series suitable for these cables. The SIM<em>Fix<\/em>\u00ae CA connectors were developed especially for 7\/8&#8243; cables. They are designed for use with cables with either copper or aluminium outer conductors. In addition to their excellent electrical performance in regard to return loss and passive intermodulation, they also guarantee resistance to ambient influences thanks to a three-stage sealing concept. This imperviousness to outdoor influences is also invaluable in such applications.<\/p>\n<div id=\"blockStyle11522Inhalt412\" class=\"six columns alpha ccm-block-styles\"><img decoding=\"async\" class=\"ccm-image-block aligncenter lazyload\" data-src=\"http:\/\/files.telegaertner.com\/6313\/9832\/8706\/SIMFix_e.jpg\" alt=\"\" width=\"320\" height=\"317\" border=\"0\" src=\"data:image\/gif;base64,R0lGODlhAQABAAAAACH5BAEKAAEALAAAAAABAAEAAAICTAEAOw==\" style=\"--smush-placeholder-width: 320px; --smush-placeholder-aspect-ratio: 320\/317;\" \/><noscript><img decoding=\"async\" class=\"ccm-image-block aligncenter\" src=\"http:\/\/files.telegaertner.com\/6313\/9832\/8706\/SIMFix_e.jpg\" alt=\"\" width=\"320\" height=\"317\" border=\"0\" \/><\/noscript><\/div>\n<div id=\"blockStyle11523Inhalt726\" class=\" ccm-block-styles\">\n<p style=\"text-align: left;\"><strong>3-fold protecion concept<\/strong><\/p>\n<p style=\"text-align: left;\"><span style=\"text-decoration: underline;\">Protection step 1:<\/span><br \/>\n<strong>An O-ring on the jacket of the cable.<\/strong>This guarantees reliable protection against the ingress of water in normal applications of an undamaged cable.<\/p>\n<p style=\"text-align: left;\"><span style=\"text-decoration: underline;\">Protection step2:<\/span><br \/>\n<strong>A special sealing to the outer conductor of the cable.<\/strong><br \/>\nDamage of the cable\u2019s outer jacket poses the danger that water will enter the connector between the outer jacket and the outer conductor of the cable. This is prevented by the additional sealing.<\/p>\n<p style=\"text-align: left;\"><span style=\"text-decoration: underline;\">Protection step3:<\/span><br \/>\n<strong>Barrier sealed by protective steps taken on centre contact.<\/strong><br \/>\nMassive destruction of the cable resulting in water ingress into the dielectric and possibly even into the inner conductor can destroy the following cable segment and even damage the base station, if water is able to seep through the connector.<\/p>\n<\/div>\n<p style=\"text-align: left;\">In the\u00a0 brochure you will find the complete range of coaxial connectors, jumper cables and surge protection which can be used in mobile radio base stations.<\/p>\n<h2 style=\"text-align: left;\">Combined signal transmission by fiber optic cables and coaxial cables<\/h2>\n<div class=\"content\" style=\"text-align: left;\">\n<div>\n<div>\n<p>Signal transmission using fiber optic cables is becoming increasingly important with the increasing use of Remote Radio Heads (RRH). Here, a digital signal is transmitted from the base station to the RRH by a fiber optic cable. The digital signal is converted into an RF signal with the appropriate carrier frequencies in the RRH. The RF signal is then transmitted over the last few metres to the antennas by corrugated coaxial cables (jumper cables). Teleg\u00e4rtner offers the suitable FO outer cables, connectors and distributor boxes for transmission over FO cables.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<p><img decoding=\"async\" class=\"ccm-image-block alignnone lazyload\" data-src=\"http:\/\/files.telegaertner.com\/9213\/8201\/9644\/Sendeanlage.JPG\" alt=\"\" width=\"725\" height=\"740\" border=\"0\" src=\"data:image\/gif;base64,R0lGODlhAQABAAAAACH5BAEKAAEALAAAAAABAAEAAAICTAEAOw==\" style=\"--smush-placeholder-width: 725px; --smush-placeholder-aspect-ratio: 725\/740;\" \/><noscript><img decoding=\"async\" class=\"ccm-image-block alignnone\" src=\"http:\/\/files.telegaertner.com\/9213\/8201\/9644\/Sendeanlage.JPG\" alt=\"\" width=\"725\" height=\"740\" border=\"0\" \/><\/noscript><\/p>\n<h2 style=\"text-align: left;\">Data transmission using twisted-pair cables and fiber optic cables within the base station<\/h2>\n<div class=\"content\">\n<p style=\"text-align: left;\">Since the RF signal is generated outside the base station when using Remote Radio Heads, twisted-pair and fiber optic cables are generally used for the data transmission inside the base station. For example, connection components in RJ45 technology or FO connectors with SC inter-faces are commonly used.<\/p>\n<p style=\"text-align: left;\">Within its wide range of connecting components for structured cabling, Teleg\u00e4rtner also offers numerous products which are ideal for use in base stations. In our new Mobile Radio brochure you will, therefore, find a broad selection of RJ45 plugs, patch cords, patch panels, FO connectors and distributor boxes as well as preassembled FO cables, all tailor-made for use in mobile radio base stations.<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Many different connecting components are used in mobile radio base stations: from coaxial connectors, jumper cords and surge pro\u2026<\/p>\n","protected":false},"author":8,"featured_media":4470,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"wds_primary_category":0,"footnotes":""},"categories":[172,167,169],"tags":[177],"class_list":["post-4481","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-coax-telegartner-special-solutions","category-solutions","category-telegartner-special-solutions","tag-----en"],"_links":{"self":[{"href":"https:\/\/www.tadafzar.com\/en\/wp-json\/wp\/v2\/posts\/4481","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.tadafzar.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.tadafzar.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.tadafzar.com\/en\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tadafzar.com\/en\/wp-json\/wp\/v2\/comments?post=4481"}],"version-history":[{"count":0,"href":"https:\/\/www.tadafzar.com\/en\/wp-json\/wp\/v2\/posts\/4481\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.tadafzar.com\/en\/wp-json\/wp\/v2\/media\/4470"}],"wp:attachment":[{"href":"https:\/\/www.tadafzar.com\/en\/wp-json\/wp\/v2\/media?parent=4481"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.tadafzar.com\/en\/wp-json\/wp\/v2\/categories?post=4481"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.tadafzar.com\/en\/wp-json\/wp\/v2\/tags?post=4481"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}